6.35/11kV XLPE Insulated, MDPE Sheathed, Armoured MV Power Cables (Three Cores)

Application

They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.

Standards

Basic design adapted to IEC 60502-2

Construction

Conductor : Plain annealed copper wire, stranded according to IEC/BS EN 60228 class 2..

Conductor Screen : Extruded layer of semi-conducting cross-linkable compound is applied over the conductor and shall cover the surface completely.

Insulation : Extruded cross-linked polyethylene (XLPE) according to IEC 60502-2&IEC 60811.

Insulaton Screen : Extruded layer of semi-conducting cross-linkable compound is applied over the insulation.

Inner Covering & Fillers : Cables shall have an inner covering over the laid-up cores. The inner covering and fillers are made of non hygroscopic material like polypropylene, except if the cable is to be made longitudinally watertight. The inner covering is extruded in general but may be lapped if the interstices between the cores are filled.

Metallic Screen : The metallic layer shall be applied over each core or applied as a collective screen. The metallic screen shall consist of either copper tapes or a concentric layer of copper wires or a combination of tapes and wires.

Separation Sheath : Thermoplastic PVC compound.

Waterproof : Water blocking tape

Bedding : Thermoplastic PVC compound.

Armour : Round Steel Wire or Steel Tape Armour

Outer Sheath : Thermoplastic MDPE compound Type ST7 according to IEC 60502-2.

COLOUR CODE

Insulation Colour : Natural colouring with coloured stripe (brown, black, grey)

Sheath Colour : Red, other colours can be offered upon request.

PHYSICAL PROPERTIES

Operating Temperature : up to 90°C

Temperature Range : -5°C

Short Circuit Temperature( 5 seconds maximum duration ) : 250°C

Bending Radius : 15 x OD

Nominal /Operating /Testing Voltages

Rated Voltage Uo/U

Operating Voltage (Um)

Testing Voltage (rms)

6.35/11KV

12KV

25.5KV


DIMENSIONAL DATA

N2XSEYR2Y (CU/XLPE/CS/PVC/SWA/PE 6.35/11kV Class 2)

Nom. Cross-Section Area

Nom. Insulation Thickness

Metallic Screen Area

Nom. Bedding Thickness

Armour wire Diameter

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

mm²

mm

mm²

mm

mm

mm

mm

kg/km

16

3.4

16

1.2

2.0

2.4

42.4

3000

25

3.4

16

1.3

2.5

2.5

46.7

3900

35

3.4

16

1.3

2.5

2.6

49.3

4430

50

3.4

16

1.4

2.5

2.7

52.6

5080

70

3.4

16

1.5

2.5

2.8

56.9

6050

95

3.4

16

1.5

2.5

2.9

61.2

7180

120

3.4

16

1.6

2.5

3.0

65.9

8230

150

3.4

25

1.7

2.5

3.1

69.6

9380

185

3.4

25

1.7

3.15

3.3

75.4

11610

240

3.4

25

1.8

3.15

3.5

82.5

14110

300

3.4

25

1.9

3.15

3.7

88.3

16420

400

3.4

35

2.0

3.5

3.9

96.0

20620

N2XSEYB2Y (CU/XLPE/CS/PVC/STA/PE 6.35/11kV Class 2)

Nom. Cross-Section Area

Nom. Insulation Thickness

Metallic Screen Area

Nom. Bedding Thickness

Armour tape Thickness

Nom. Sheath Thickness

Approx. Overall Diameter

Approx. Weight

mm²

mm

mm²

mm

mm

mm

mm

kg/km

16

3.4

16

1.2

0.5

2.3

40.5

2680

25

3.4

16

1.3

0.5

2.4

43.7

3195

35

3.4

16

1.3

0.5

2.5

46.2

3720

50

3.4

16

1.4

0.5

2.6

48.8

4200

70

3.4

16

1.5

0.5

2.7

52.8

5185

95

3.4

16

1.5

0.5

2.8

56.9

6280

120

3.4

16

1.6

0.5

2.9

60.5

7360

150

3.4

25

1.7

0.5

3.0

63.9

8420

185

3.4

25

1.7

0.5

3.1

68.2

9910

240

3.4

25

1.8

0.5

3.3

73.8

12200

300

3.4

25

1.9

0.5

3.4

79.1

14530

400

3.4

35

2.0

0.8

3.7

87.7

18600